| Sun Alert
|
Former ID
|
Synopsis
|
Last Modified Date
|
| 228538 | 101473 |
Sun Fire 12K/15K May Experience I2C Timeouts When SMS is Simultaneously Started on Both System Controllers |
2005-06-21
|
| 228395 | 102819 |
Memory Shortage on Sun Fire 12K/15K CP1500 System Controllers Running Solaris 10 |
2007-12-17
|
| 201711 | 101245 |
Sun Fire 12K or Sun Fire 15K Domain May "Dstop" When Another Domain That Shares an Expander Board is Shutdown |
2003-07-28
|
| 201595 | 101795 |
The First POST Following a Power Cycle May Fail SUBTEST=Memory Addressing ID=61.1 |
2005-09-02
|
| 201571 | 102020 |
Under Certain Conditions, Solaris 10 Patch 118822-11 Through 118822-23 May Cause a System Panic on Some Servers |
2006-01-18
|
| 201490 | 101326 |
Patch 114608-05 is WITHDRAWN, May Generate a "Dstop" on Sun Fire 12K/15K With Shared Expander Configuration |
2003-09-08
|
| 201458 | 101310 |
Sun Fire 12K/15K Domains May Experience Device Timeouts During SMS Startup Resulting in "Dstop" |
2003-10-14
|
| 201435 | 101361 |
Sun UltraSPARC Servers May Hang on Reboot After Running "probe-scsi" Command |
2003-10-01
|
| 201342 | 103016 |
Sun Fire 12K/15K/E20K/E25K Domains Running Solaris 8 2/04 May Experience Bus Error When Using Dynamic Reconfiguration |
2008-06-20
|
| 201307 | 101204 |
Sun Fire 12K and Sun Fire 15K Domain May Panic or "Dstop" During the Reboot Sequence |
2003-05-06
|
| 201240 | 101170 |
Sun Fire Servers May not Report the Correct DIMM Location after Dynamic Reconfiguration (DR) Event |
2003-03-06
|
| 201236 | 101174 |
Sun Fire 3800/4800/4810/6800, Sun Fire 12K/15K, Sun Fire V1280, and Netra 1280 Server Domains with 900MHz CPUs May Panic or Hang Due to Incorrect L2 SRAM Parameter Settings |
2003-03-17
|
| 201215 | 101379 |
Sun Fire 3800/4800/4810/6800 and Sun Fire 12K/15K Servers With Certain UltraSPARC III Based System Boards Shipped Between 14-Apr-2003 and 03-Oct-2003 May Experience System Interrupts Due to Processor Attach Mechanism Issues |
2004-05-24
|
| 201212 | 101452 |
On Sun Fire Servers, Using Dynamic Reconfiguration (DR) on System Boards With Permanent Memory May Fail Due to a Non Responsive QLC Driver |
2004-03-18
|
| 201208 | 101234 |
CPU0/CPU1 May Be Disabled on Sun Fire 12K/15K System Boards Resulting in Domain Interruption |
2004-01-08
|
| 201200 | 101443 |
Sun Fire 12K/15K Servers With 1200 MHz Uniboards Running System Management Software (SMS) 1.4 May Experience L2SRAM Errors |
2004-02-02
|
| 201176 | 101626 |
Replacing an Expander Board on a Running Sun Fire 12K/15K/20K/25K Platform May Result in a Global Domain Stop (Dstop) |
2004-12-17
|
| 201062 | 102960 |
Patches 121688-03, 121689-03, and 124460-02 are WITHDRAWN - Certain Sun Fire Systems May Experience "consistent dma sync timeout" or System Panic When Using "Stop-A" |
2007-08-13
|
| 201002 | 101561 |
Sun Fire F12K/F15K/E20K/E25K Platforms With CP2140 Based System Controllers May Take Several Hours for I2 Network Initialization |
2004-08-27
|
| 200992 | 101631 |
Patch 118051-03 WITHDRAWN Due to Transgression Errors |
2004-12-23
|
| 200990 | 101635 |
When Net Connect 3.1.1 is Installed but Not Activated, the Systems Management Software (SMS) Event Reporting Daemon (erd) May Fail to Start |
2005-02-18
|
| 200868 | 102975 |
Sun Fire 12K/15K/20K/25K System Controller Management (scman) Networks May Fail After Applying Patch 122608-01 through 122608-03 |
2007-06-27
|
| 200848 | 101064 |
DR Operations may Hang the Domain on E10K and Sun Fire Servers if Domains are "hardened" with Security Tools |
2003-01-24
|
| 200845 | 101205 |
Sun Fire 12K or Sun Fire 15K System Controller(SC) may Encounter a Failover Management Daemon Failure and Cause a Domain to Dstop |
2003-03-20
|
| 200742 | 101183 |
On Sun Systems, a Small Number of 256MB DIMMs May Experience Premature Failures with Uncorrectable Memory Error (UE) Messages |
2004-03-23
|
| 200634 | 103148 |
Sun Fire Systems Equipped With UltraSPARC IV+ Processor Modules Running Solaris 9 or Solaris 10 may Exhibit Unnecessary CPU Offlining and Solaris Panics |
2008-06-24
|
| 200584 | 101209 |
Sun Fire 12K/15K Domains with MaxCPUs in Split Expanders May "Dstop" with an "Undefined TTransID (UTT)" |
2008-04-02
|
| 200574 | 101197 |
Sun Fire 12K or Sun Fire 15K Domain may DSTOP When Another Domain Reboots or is Shutdown |
2003-03-18
|
| 200565 | 101237 |
A Sun Fire 12K/15K System Controller's Floating IP Address May Not Failover to The Alternate System Controller |
2003-04-23
|
| 200508 | 101566 |
A Limited Subset of Sun Fire System/Processor Boards May be Vulnerable to Uncorrectable Errors in its L2 SRAM |
2005-07-28
|
| 200352 | 101421 |
Sun Fire 12K/15K Domain May "Dstop" When Another Domain Sharing an Expander is Performing a "setkeyswitch on/off" or a DR Operation |
2004-01-06
|
| 200289 | 101502 |
On Rare Occasions, Sun Fire 12K/15K/20K/25K Servers May Experience an Unexpected "Dstop" During a Recovery POST |
2004-05-25
|
| 200020 | 101667 |
A Limited Subset of DIMMs (less than 1%) Shipped in 2001-2002 May Have a Reliability Issue |
2006-06-13
|